Siemens · DCM
A time slice overflow has occurred within the power unit, indicating that a critical internal process exceeded its allocated computational time. This can lead to system instability, incorrect operation, or a complete shutdown. The fault requires immediate attention to prevent further operational issues.
Click steps to track your progress.
Perform a complete power cycle of the drive system (main power off/on) to reset the power unit's internal processor.
Reduce the motor's operating conditions (e.g., lower speed, reduce load) if the fault occurs during heavy operation.
Review and potentially reduce the PWM switching frequency parameter (e.g., P1800) if it is set to a very high value, which increases processor load.
Ensure the power unit's firmware is updated to the latest stable version, as updates often include performance improvements and bug fixes.
If the fault persists, back up drive parameters and attempt a factory reset of the power unit, then reload the parameters.