Siemens · SINAMICS G120
A safety-related parameter has been modified either during safety commissioning or a safety reset. This warning is issued to ensure that all safety changes are intentionally acknowledged and finalized, as unresolved changes can prevent the drive from entering a safe operational state, potentially compromising machine safety.
Click steps to track your progress.
1. Review all safety-related parameters (e.g., those in the P09xx series) to identify which ones have been modified since the last acknowledgment.
2. Acknowledge the safety parameter changes by setting parameter P0976 (Safety acknowledge) to the required value (e.g., 1 or 2) after verifying them.
3. If safety parameters were changed via a PLC or safety controller, ensure the configuration matches the drive's expectations and then re-acknowledge.
4. Perform a safety commissioning procedure as detailed in the drive's safety manual, including signature generation if applicable.
5. If changes were unintentional, load the last known good safety parameter set from a backup file and then acknowledge the restore via P0976.