Siemens · SINAMICS G120
A semaphore problem occurred during startup, preventing the drive from loading its last saved safety parameters and forcing it to load default values instead. This indicates a data integrity issue or timing problem, compromising the intended safety configuration and requiring immediate attention to restore safe operation.
Click steps to track your progress.
1. Perform a safety parameter reset (e.g., P0970=95) and then reconfigure all safety parameters according to the machine's safety documentation.
2. Reload the safety parameters from a known good backup file using the engineering software (e.g., STARTER) and then acknowledge the changes (P0976).
3. Update the drive's firmware to the latest stable version to address any potential software bugs related to parameter storage.
4. Verify the integrity of the power supply to the drive, checking for voltage sags or interruptions during startup sequences.
5. If the issue persists after reconfiguring and reloading, consider replacing the main control board as a memory hardware fault may be present.