The safety reset or safety commissioning process is currently active, indicated by parameter p0010 = 95. This prevents normal drive operation until the safety procedure is properly concluded, ensuring that all safety configurations are finalized and verified for safe machine control.
Click steps to track your progress.
1. Navigate to parameter P0010 and ensure it is not set to 95; if it is, complete the safety commissioning steps as per the drive manual or set it back to 0.
2. Acknowledge any pending safety parameter changes by setting parameter P0976 (Safety acknowledge) to the required value (e.g., 1 or 2).
3. Review the drive's safety manual for the specific procedure to correctly exit the 'Safety commissioning active' state.
4. Save all parameters to non-volatile memory (e.g., P0971=1) after confirming the safety configuration and commissioning status.
5. Power cycle the drive and check P0010 again to ensure the safety commissioning mode has been exited successfully.