Siemens · SINAMICS G120
A problem has occurred during data backup to the Non-Volatile RAM (NVRAM), potentially leading to loss of configuration data if power is removed. This indicates a critical memory or hardware issue that could result in needing to reconfigure the drive after a power cycle.
Click steps to track your progress.
1. Cycle power to the drive system and attempt to save parameters again (e.g., via p0971 or commissioning software).
2. Verify the stability of the 24VDC control power supply to the Control Unit, measuring voltage levels during save attempts.
3. Perform a firmware update on the Control Unit to the latest stable version to address potential software bugs.
4. Back up all parameters to an external engineering tool (e.g., STARTER) and then perform a factory reset (p0010=30, p0970=1) to clear potentially corrupted NVRAM.
5. If the fault persists after firmware update and factory reset, consider replacing the Control Unit as the NVRAM may be defective.