58

Brake Fault

Vacon · NX All-in-One Application

What does 58 mean?

This fault occurs when the actual status of the mechanical brake does not match the drive's control signal. This mismatch indicates a problem with the brake mechanism itself or its feedback system, potentially leading to uncontrolled movement or inability to stop.

Common Causes

  • Mechanical brake not releasing or engaging properly.
  • Brake control circuit failure or incorrect wiring.
  • Brake coil shorted or open.
  • Insufficient voltage to the brake actuator.
  • Brake position feedback signal faulty or out of range.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Inspect the mechanical state of the brake for proper engagement and disengagement.

  2. 2

    Verify all electrical connections to the brake and its feedback sensors for integrity and proper wiring.

Browse all codes in this manual (42)
Verified technical data. Last updated: April 2026

Related Faults

1Overcurrent10Input line supervision11Output phase supervision
Source: Vacon NX All-in-One Application
Open Manual (Page 377)Search more codes in this manual