Vacon · NXS NXP
The drive's start-up sequence has been inhibited, typically because a run request signal was active while a new application program was being downloaded or after a configuration change. This is a safety feature designed to prevent unintended motor starts. The drive will not initiate operation until this preventative condition is safely resolved.
Click steps to track your progress.
Verify all run commands (e.g., digital inputs, fieldbus commands, local control panel) are deactivated before attempting further configuration or power cycling.
Check the status of safety inputs (e.g., OPTAF board inputs, dedicated STO terminals) and ensure they are in a safe (inactive) state, then cycle power if required.
Confirm any critical parameter changes (e.g., P0-00 for application type) have been saved to EEPROM and the drive has been power cycled as prompted.
Reset any active "Quick Stop" or "Emergency Stop" conditions via their respective inputs or software commands.
Review parameter settings related to start-up control (e.g., P2-01 "Start function") to ensure they align with the current operational mode.