38

Device added (same type)

Vacon · NXS NXP

What does 38 mean?

An option board of the same type, which was previously used in the same slot, has been added to the drive. The drive recognizes the board and has its parameters available. This is primarily an informational alarm, indicating the drive is ready to use the previously stored settings for this specific board.

Common Causes

  • An option board that was previously installed in a specific slot (and its parameters saved) was re-inserted into the same slot after removal.
  • The drive's internal memory retains the configuration data for that slot, and upon re-detection of the same board type, it presents the stored parameters.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Acknowledge the informational fault message in the drive's display or software. This fault typically does not require corrective action for functionality.

  2. 2

    Verify that the parameters associated with the option board are correctly applied and suitable for the current application.

  3. 3

    If parameters need adjustment, modify them as required and save the new configuration.

  4. 4

    Confirm the option board is properly seated and secured in its slot.

  5. 5

    No further troubleshooting is typically needed as this is an expected informational message.

Browse all codes in this manual (54)
Verified technical data. Last updated: April 2026