12

Brake Chopper Supervision Fault

Vacon · NX Liquid-Cooled Drive

What does 12 mean?

This fault indicates a problem with the brake chopper system. Possible causes include the absence of a brake resistor, a broken or open-circuited brake resistor, or a failure of the brake chopper circuitry itself.

Common Causes

  • Brake chopper resistor disconnected or faulty.
  • Brake chopper output short-circuited.
  • DC bus voltage too high during braking, exceeding chopper limits (P0400).

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Verify that a brake resistor is correctly installed and connected to the drive terminals.

  2. 2

    Measure the resistance of the brake resistor to ensure it is not broken or open-circuited.

  3. 3

    Inspect the cabling between the drive and the brake resistor for any damage or loose connections.

Browse all codes in this manual (52)
Verified technical data. Last updated: March 2026

Related Faults