Yaskawa · E7 Drive
A minor fault was detected during the auto-tuning process. This could indicate slight discrepancies in input data, wiring issues, or problems with the mechanical load connected to the motor, impacting the accuracy of tuning.
Click steps to track your progress.
1. Re-verify all motor nameplate data entered into parameters (e.g., P3-01, P3-02, P3-04) against the physical motor label.
2. Inspect motor wiring connections for tightness at both the drive output terminals (U, V, W) and the motor terminal box.
3. Manually rotate the motor shaft to check for any slight binding or unusual resistance.
4. Ensure the motor is operating at its normal operating temperature before initiating auto-tuning.
5. Try running the auto-tuning process again, ensuring no external disturbances during the procedure.
6. If the drive supports different auto-tuning modes (e.g., static vs. dynamic), try an alternative mode.