Yaskawa · E7 Drive
This fault signifies a critical motor overtemperature condition where the analog temperature input (H3-09=E) has exceeded the OH4 fault threshold (2.34V). This level typically triggers a drive stop (based on L1-04) to prevent severe and permanent motor damage due to excessive heat.
Click steps to track your progress.
1. Immediately stop the motor and allow it to cool down to a safe temperature before any further inspection.
2. Measure the analog input voltage at H3-09 and verify it against the sensor's specifications for the current motor temperature.
3. Inspect the motor's cooling system (fan, fins, liquid cooling if applicable) for blockages or failures.
4. With power off, measure the motor winding resistance and insulation resistance to ground with a megohmmeter.
5. Using a clamp meter, measure and compare the drive output currents (U, V, W) for phase balance after a brief restart attempt.