Yaskawa · GA500 Maintenance and Troubleshooting
This fault indicates an issue originating from the DriveWorksEZ program itself, not a drive hardware fault. It signifies a problem with the user-defined logic or configuration which prevents proper program execution on the drive.
Click steps to track your progress.
1. Connect to the drive using DriveWorksEZ software and upload the current program.
2. Review the DriveWorksEZ program code for logical errors, infinite loops, or incorrect variable usage.
3. Debug the DriveWorksEZ program using simulation mode, observing variable states and program flow.
4. Verify all parameter references (e.g., P1-01, H1-01) within the DriveWorksEZ logic are valid for the drive model.
5. Download a previously working version of the DriveWorksEZ program, if available, to isolate the issue to recent changes.