Yaskawa · J1000
A self-diagnostics problem has occurred within the watchdog circuit, which is responsible for monitoring the CPU's operation and resetting it if it becomes unresponsive. This indicates an internal hardware failure where the CPU is not responding as expected, causing the drive to enter a fault state and cease operation.
Click steps to track your progress.
1. Verify the integrity of the main control board for visible damage (e.g., burned components, swollen capacitors).
2. Measure the input AC power supply stability (voltage and frequency) at L1/L2/L3 terminals using a true RMS multimeter.
3. Check grounding impedance of the drive chassis to earth ground, ensuring it is below 1 Ohm.
4. Isolate the drive from external control signals and motor connections, then power cycle to check for self-recovery.
5. Collect drive diagnostic logs via communication interface (e.g., using DriveWorks software) before replacing the drive.