Yaskawa · J1000
An external fault condition has been received by the drive from the PLC via an option card. The drive's response (stopping or continuing to run as an alarm) depends on the F6-03 parameter setting. This fault typically points to an issue originating from an external device, a problem with the PLC program's fault handling, or a communication issue.
Click steps to track your progress.
Access the drive's fault history (e.g., parameter U1-10) to confirm the EF0 fault and its timestamp.
Check the status indicators (LEDs) on the option card for specific fault or communication error indications.
Verify the communication link (e.g., Ethernet cable, serial cable) between the option card and the external PLC for continuity and secure connections.
Review the PLC program for any active fault bits or registers being written to the option card's designated fault input address.
Confirm the option card's external fault monitoring parameter (e.g., F6-03 or a card-specific parameter) is set correctly for the intended fault response.
If available, try swapping the option card with a known good spare to isolate a potential hardware defect.