E2051

Motor overtemp. prewarning

Bosch Rexroth · IndraDrive C Drive Controllers

¿Qué significa E2051 ?

This is a prewarning indicating that the motor temperature has reached an elevated level, approaching its thermal limits. Continued operation at this temperature could lead to motor damage or a full shutdown.

Causas comunes

  • Motor running at excessive load for extended periods.
  • Inadequate motor cooling due to blocked vents, fan failure, or high ambient temperature.
  • Incorrect motor parameters configured in the drive, leading to improper current control.
  • Faulty motor temperature sensor or wiring.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Check the mechanical load on the motor and ensure it is within specified limits for continuous operation.

  2. 2

    Verify the motor's cooling system (fans, fins) is clean and functioning correctly. Ensure adequate airflow around the motor.

  3. 3

    Inspect motor cabling and connections for damage or loose terminals that could cause increased resistance and heat.

  4. 4

    Review drive parameters related to motor thermal model and current limits. Compare with motor nameplate data.

  5. 5

    Monitor the motor temperature using external means if possible, and compare with the drive's reported temperature to verify sensor accuracy.

Ver todos los códigos en este manual (66)
Datos técnicos verificados. Última actualización: March 2026