E2055

Feedrate override S-0-0108 = 0

Bosch Rexroth · IndraDrive C Drive Controllers

¿Qué significa E2055 ?

The feedrate override parameter S-0-0108 is set to zero, effectively stopping all motion. This prevents any velocity or position commands from being executed.

Causas comunes

  • Feedrate override parameter S-0-0108 was intentionally or accidentally set to 0.
  • External PLC or HMI command setting the feedrate override to 0.
  • System logic error preventing the override value from being set above 0.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Verify the value of parameter S-0-0108 (Feedrate override) in the drive controller and ensure it is set to a non-zero value.

  2. 2

    Check the machine's HMI or control program for any active feedrate override settings that might be forced to 0.

  3. 3

    Trace the logic controlling S-0-0108 to ensure no unexpected conditions are setting it to zero.

  4. 4

    If controlled externally, check the master communication for valid override values.

Ver todos los códigos en este manual (66)
Datos técnicos verificados. Última actualización: March 2026