Traduciendo...
E2061
Device overload prewarning
Bosch Rexroth · IndraDrive C Drive Controllers
¿Qué significa E2061 ?
The drive controller or associated power electronics are experiencing an elevated load, approaching their thermal capacity. Continued operation at this level could lead to a device shutdown.
Causas comunes
- Continuous operation at or above the drive's rated current.
- Motor operating under excessive mechanical load.
- Inadequate cooling for the drive controller, possibly due to blocked vents, fan failure, or high ambient temperature.
- Incorrect drive parameters (e.g., motor data) causing the drive to misinterpret its internal load.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Verify the mechanical load on the motor and ensure it is within the drive's continuous operating current limits.
- 2
Check the drive's cooling fan for proper operation and ensure ventilation openings are clear of obstructions.
- 3
Measure the ambient temperature around the drive and ensure it is within the specified operating range.
- 4
Review drive parameters for motor current, load limits, and thermal model settings to ensure they are configured correctly.
Datos técnicos verificados. Última actualización: March 2026
Fallas relacionadas
Fuente: Bosch Rexroth IndraDrive C Drive Controllers