Traduciendo...
E2086

Prewarning supply module overload

Bosch Rexroth · IndraDrive C Drive Controllers

¿Qué significa E2086 ?

The supply module is experiencing an elevated load, approaching its thermal capacity. This prewarning indicates that continuous operation at this level could lead to a shutdown of the supply module or the entire system.

Causas comunes

  • Continuous operation at or above the supply module's rated current.
  • Motor or mechanical system experiencing excessive load or regeneration.
  • Inadequate cooling for the supply module, possibly due to blocked vents, fan failure, or high ambient temperature.
  • Incorrect configuration or undersized supply module for the application.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Verify the total current draw from the supply module and ensure it is within its continuous operating limits.

  2. 2

    Check the supply module's cooling fan for proper operation and ensure ventilation openings are clear of obstructions.

  3. 3

    Measure the ambient temperature around the supply module and ensure it is within the specified operating range.

  4. 4

    Review the application's duty cycle and peak loads; consider reducing load or increasing acceleration/deceleration times if possible.

Ver todos los códigos en este manual (66)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas

Fuente: Bosch Rexroth IndraDrive C Drive Controllers