E2818

Phase failure

Bosch Rexroth · IndraDrive C Drive Controllers

¿Qué significa E2818 ?

One or more phases of the incoming AC mains power supply are missing or significantly unbalanced. This can cause severe operational issues and damage to the drive.

Causas comunes

  • Loss of one or more phases in the incoming AC mains supply.
  • Blown fuse or tripped circuit breaker in one phase.
  • Loose or open connection in the mains power cabling.
  • Faulty contactor or circuit breaker.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Check all three phases of the incoming AC mains voltage (L1-L2, L2-L3, L3-L1) for balance and presence.

  2. 2

    Inspect all fuses and circuit breakers in the mains power circuit and replace any blown fuses or reset tripped breakers.

  3. 3

    Verify all power connections from the mains supply to the drive for tightness and continuity.

  4. 4

    Check the functionality of any upstream contactors or phase monitoring relays.