Motor overload, current limit active
Bosch Rexroth · IndraDrive C Drive Controllers
¿Qué significa E8055 ?
The motor is experiencing an overload condition, and its current has reached the configured limit. This indicates that the motor is being driven beyond its continuous operating capacity, posing a risk of overheating.
Causas comunes
- Excessive mechanical load on the motor.
- Continuous operation above the motor's rated current.
- Incorrect motor parameters in the drive's configuration.
- Mechanical binding or obstruction in the system.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Reduce the mechanical load on the motor to within its continuous operating specifications.
- 2
Verify that the motor parameters (e.g., rated current, thermal model) in the drive are correctly configured to match the motor nameplate.
- 3
Inspect the mechanical system for any binding, misalignment, or excessive friction that could cause an overload.
- 4
Check the application's duty cycle to ensure the motor is not continuously operating in overload conditions.