F2005
Cam shaft invalid
Bosch Rexroth · IndraDrive C Drive Controllers
¿Qué significa F2005 ?
The configured cam shaft profile or parameters are invalid, incomplete, or corrupted. This prevents the drive from executing cam-based motion profiles.
Causas comunes
- Invalid data or format in the cam shaft table.
- Incorrect number of cam points or interpolation parameters.
- Memory corruption affecting the cam shaft data.
- Attempting to activate a cam shaft that has not been properly defined or loaded.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Verify the cam shaft table data, including the number of points, interpolation methods, and segment definitions, against the application requirements.
- 2
Reload the cam shaft profile into the drive controller to correct any potential data corruption.
- 3
Check parameters related to cam shaft selection and activation to ensure the correct cam is being referenced.
- 4
Consult the programming manual for correct cam shaft definition and parameterization procedures.