F2006

MMC was removed

Bosch Rexroth · IndraDrive C Drive Controllers

¿Qué significa F2006 ?

The MultiMediaCard (MMC) containing drive parameters, firmware, or application data has been removed or is no longer detected. This prevents the drive from loading necessary configuration and operating.

Causas comunes

  • MMC card physically removed from the drive slot.
  • MMC card improperly seated or loose in the slot.
  • Faulty MMC card or damaged drive card reader.
  • Vibration or shock causing the card to dislodge.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Ensure the MMC card is correctly and securely inserted into its slot on the drive controller.

  2. 2

    Check the MMC card for any physical damage or contamination on its contacts.

  3. 3

    If possible, try re-seating the MMC card multiple times or using a known good MMC card to rule out card failure.

  4. 4

    Verify the integrity of the MMC card's contents by attempting to read it on a compatible device if available.

Ver todos los códigos en este manual (66)