Traduciendo...
F2008
The motor type has changed.
Bosch Rexroth · IndraDrive C Drive Controllers
¿Qué significa F2008 ?
The drive has detected a change in the connected motor type compared to the previously stored configuration. This requires a parameter adjustment to ensure correct motor control.
Causas comunes
- The physical motor connected to the drive has been replaced with a different type or model.
- Motor parameters in the drive's configuration have been changed to a different motor type without confirmation.
- A drive configuration (e.g., from MMC) for a different motor has been loaded.
- Internal drive error misidentifying the motor.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Verify that the currently connected motor matches the motor type configured in the drive's parameters. Compare motor nameplate data.
- 2
If the motor was replaced, update the drive parameters to match the new motor's specifications. This may require recalibration.
- 3
If a different configuration was loaded, ensure it corresponds to the actual motor connected.
- 4
Acknowledge the motor type change in the drive's software, if prompted, and save the new configuration.
Datos técnicos verificados. Última actualización: March 2026
Fallas relacionadas
Fuente: Bosch Rexroth IndraDrive C Drive Controllers