F2031

Encoder 1 error: signal amplitude incorrect

Bosch Rexroth · IndraDrive C Drive Controllers

¿Qué significa F2031 ?

The analog signal amplitude from encoder 1 is outside the expected range, indicating a problem with the encoder, its cabling, or the drive's input circuit. This affects position and velocity feedback accuracy.

Causas comunes

  • Faulty encoder hardware or aging components.
  • Damaged or improperly shielded encoder cabling.
  • Incorrect termination or impedance matching for the encoder signals.
  • Damage to the drive's encoder input circuit.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Inspect the cabling for encoder 1 for physical damage, proper shielding, and secure connections. Check for proper signal ground connections.

  2. 2

    Verify the encoder's power supply voltage at the encoder terminals. Incorrect voltage can affect signal amplitude.

  3. 3

    If possible, use an oscilloscope to measure the differential signal amplitude of the encoder at the drive's input. Compare with the encoder's specifications.

  4. 4

    Check drive parameters related to encoder input configuration, such as termination settings. If the fault persists, the encoder or drive input may be defective.

Ver todos los códigos en este manual (66)