F2039

Maximum acceleration exceeded

Bosch Rexroth · IndraDrive C Drive Controllers

¿Qué significa F2039 ?

The actual acceleration or the commanded acceleration has exceeded the configured maximum limit for the axis. This can cause mechanical stress or control instability.

Causas comunes

  • Programmed acceleration command is higher than the drive's configured maximum acceleration limit.
  • External mechanical force or uncontrolled motion causing unexpected acceleration.
  • Drive parameters for maximum acceleration are set too low for the application's dynamics.
  • Incorrectly tuned velocity loop or current loop causing overshoots.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Check the commanded acceleration value in the motion program or HMI and ensure it is within the drive's configured maximum acceleration limits.

  2. 2

    Verify the drive parameter for maximum acceleration and adjust it if necessary, ensuring it is appropriate for the application and mechanical system.

  3. 3

    Inspect the mechanical system for any sudden load changes or external forces that could cause unexpected acceleration.

  4. 4

    Review the velocity and current loop tuning parameters for stability.

Ver todos los códigos en este manual (66)