SP0021

Position Sensor Polarity Setting Incorrect

Fanuc · AC Spindle Motor Alpha i-Beta i Series Parameters

¿Qué significa SP0021 ?

The polarity setting for the position sensor is incorrect. This can lead to incorrect position feedback and unstable spindle control.

Causas comunes

  • Position sensor cable wired with reversed polarity.
  • Incorrect setting of position sensor type in CNC parameters.
  • Faulty position sensor unit.
  • Electrical noise interfering with sensor feedback signal.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Verify position sensor wiring according to manufacturer diagram (e.g., A/B phase, Z pulse).

  2. 2

    Adjust parameter P4-XX (position sensor type) to match installed sensor.

  3. 3

    Measure sensor output signals for correct phase sequence.

  4. 4

    Install shielded cabling for position sensor to reduce noise.