Traduciendo...
SP0996

Incorrect Spindle/Motor Assignment (15i)

Fanuc · AC Spindle Motor Alpha i-Beta i Series Parameters

¿Qué significa SP0996 ?

The assignment of spindles and spindle motors for Series 15i is incorrect. This can lead to improper control or system conflicts due to mismatched configuration.

Causas comunes

  • Incorrect assignment of spindle drive numbers in parameters.
  • Mismatched motor identification signals between CNC and amplifier.
  • Faulty encoder feedback from the spindle motor.
  • Configuration error in parameters defining motor polarity or feedback type.
  • Software logic error in the CNC's spindle assignment module.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Verify parameter P2-01 (and related spindle assignment parameters) match the physical connections.

  2. 2

    Check that encoder feedback signals (e.g., A, B, Z phases) are correctly connected to the amplifier.

  3. 3

    Inspect the encoder cable for continuity and signal integrity.

  4. 4

    Perform a motor identification test via the CNC menu.

  5. 5

    Ensure the motor nameplate data matches the configured parameters in the CNC.

Ver todos los códigos en este manual (60)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas

Fuente: Fanuc AC Spindle Motor Alpha i-Beta i Series Parameters