0475
Observer Parameter (POA1) Overflow
Fanuc · Alpha i Series Servo Amplifier
¿Qué significa 0475 ?
This invalid parameter setting alarm indicates that the internal calculation value of the observer parameter POA1 has overflowed. This suggests an incorrect setting for the observer parameter, causing internal calculation limits to be exceeded.
Causas comunes
- Observer parameter (POA1) calculation has overflowed.
- Disturbances affecting observer state prediction.
- Faulty observer gain tuning (P04-65).
- Rapid acceleration/deceleration transients.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Correct the setting of the observer parameter to (-1) × (desired value)/10.