Traduciendo...
0535
Dead Zone Compensation Parameter Overflow
Fanuc · Alpha i Series Servo Amplifier
¿Qué significa 0535 ?
This invalid parameter setting alarm indicates that the internal calculation value of a parameter related to dead zone compensation has overflowed. This typically happens when the compensation setting is too high, leading to mathematical limits being exceeded.
Causas comunes
- Dead zone compensation parameter calculation has overflowed.
- Excessive mechanical slack or play in the drive train.
- Improper dead zone compensation tuning (P04-12).
- Variable friction characteristics.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Decrease the setting of the parameter related to dead zone compensation to the extent that the invalid parameter setting alarm is no longer caused.
Datos técnicos verificados. Última actualización: March 2026
Fallas relacionadas
Fuente: Fanuc Alpha i Series Servo Amplifier