Traduciendo...
0544
Dead Zone Compensation Parameter Overflow
Fanuc · Alpha i Series Servo Amplifier
¿Qué significa 0544 ?
This invalid parameter setting alarm indicates that the internal calculation value of a parameter related to dead zone compensation has overflowed. This typically happens when the compensation setting is too high, leading to mathematical limits being exceeded.
Causas comunes
- Dead zone compensation parameter calculation has overflowed.
- System unable to effectively compensate for nonlinearities.
- Parameter for dead zone estimation (P04-12) is too aggressive.
- Significant backlash in gearboxes or couplings.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Decrease the setting of the parameter related to dead zone compensation to the extent that the invalid parameter setting alarm is no longer caused.
Datos técnicos verificados. Última actualización: March 2026
Fallas relacionadas
Fuente: Fanuc Alpha i Series Servo Amplifier