0883
Serial Separate Detector Machine Velocity Feedback Coefficient Exceeded
Fanuc · Alpha i Series Servo Amplifier
¿Qué significa 0883 ?
This invalid parameter setting alarm occurs for an axis equipped with a serial type separate detector when the machine velocity feedback coefficient is set to a value exceeding 100. The upper limit for this coefficient on such axes is strictly 100, and exceeding it causes an error.
Causas comunes
- The machine velocity feedback coefficient has exceeded the maximum allowed value.
- The serial separate detector is reporting an excessively high velocity feedback.
- Parameter P601.1 (Serial Velocity Feedback Coefficient) is too high.
- An internal overflow occurred when processing the serial detector's velocity data.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Correct the machine velocity feedback coefficient so that its value does not exceed 100 for axes with a serial type separate detector.
Datos técnicos verificados. Última actualización: March 2026