Traduciendo...
0885
Machine Velocity Feedback Coefficient Overflow
Fanuc · Alpha i Series Servo Amplifier
¿Qué significa 0885 ?
This invalid parameter setting alarm indicates that the internal calculation value of the machine velocity feedback coefficient has overflowed. This usually happens if the coefficient is set too high, exceeding internal processing limits.
Causas comunes
- The calculated machine velocity feedback coefficient is too high.
- A sensor reading related to machine speed has overflowed during coefficient calculation.
- Parameter P601.2 (Velocity Feedback Coefficient) is set too high.
- An internal process overflowed during the calculation of the velocity feedback gain.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Decrease the machine velocity feedback coefficient.
- 2
Alternatively, utilize the vibration-damping control function, which offers an equivalent effect.
Datos técnicos verificados. Última actualización: March 2026
Fallas relacionadas
Fuente: Fanuc Alpha i Series Servo Amplifier