Traduciendo...
10019

Runaway Detection Parameter Overflow

Fanuc · Alpha i Series Servo Amplifier

¿Qué significa 10019 ?

This invalid parameter setting alarm indicates that the internal calculation value of a parameter related to runaway detection has overflowed. This suggests an issue with the runaway detection function's configuration, leading to computational errors.

Causas comunes

  • The parameter used for runaway detection has overflowed its valid range.
  • An internal calculation for runaway detection exceeded the maximum value.
  • Parameter P100.1 (Runaway Threshold) is set excessively high.
  • Sensor data used for runaway detection is abnormally large.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Disable the runaway detection function by setting bit 0 of parameter 1740 (Series 15) or 2200 (Series 16, etc.) to 1.

Ver todos los códigos en este manual (101)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas

Fuente: Fanuc Alpha i Series Servo Amplifier
Fanuc 10019 (Runaway Detection Parameter Overflow) — Refere… | ErrorLib