Alarm 6

Software Disconnection (α Pulse Coder)

Fanuc · Alpha i Series Servo Amplifier

¿Qué significa Alarm 6 ?

This alarm is issued when the absolute position data sent from the built-in α pulse coder cannot be synchronized with the phase data.

Causas comunes

  • The alpha pulse coder (encoder) has lost its signal.
  • Software error related to the alpha pulse coder interface.
  • Encoder is not transmitting valid data.
  • Faulty connection or internal encoder issue affecting the alpha signal.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Turn off the NC (Numerical Control) power.

  2. 2

    Remove the pulse coder cable.

  3. 3

    Attach the pulse coder cable again securely.

  4. 4

    If this alarm is issued again after re-attaching the cable, replace the pulse coder.

Ver todos los códigos en este manual (101)