Traduciendo...
SV0304

APC ALARM: PARITY ERROR

Fanuc · Alpha i Series Servo Amplifier

¿Qué significa SV0304 ?

A parity error was detected during data transfer from the absolute-position detector, making it impossible to obtain the correct machine position. This error points to a potential defect in the absolute-position detector, its cable, or the servo interface module.

Causas comunes

  • Parity bit error in the data transmitted by the APC.
  • Corrupted data bits in the transmission stream.
  • Faulty APC encoder generating incorrect parity.
  • Environmental noise corrupting data during transfer.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Verify parity setting (even/odd) in CNC communication parameters.

  2. 2

    Measure APC encoder output for signal integrity and bit stability.

  3. 3

    Check APC encoder for loose internal connections.

  4. 4

    Shield communication cables to prevent external interference.

Ver todos los códigos en este manual (101)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas

Fuente: Fanuc Alpha i Series Servo Amplifier