Traduciendo...
SV0305

APC ALARM: PULSE ERROR

Fanuc · Alpha i Series Servo Amplifier

¿Qué significa SV0305 ?

A pulse error occurred with the absolute-position detector, preventing the system from obtaining the correct machine position. This issue is typically caused by a defect in the absolute-position detector or its connecting cable.

Causas comunes

  • APC encoder pulse generation is inconsistent or faulty.
  • Signal degradation of the encoder's pulse output.
  • Incorrect pulse counting by the CNC.
  • Mechanical issues affecting the encoder's disc rotation.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Measure APC encoder pulse output (e.g., A, B signals) for correct waveform and frequency.

  2. 2

    Inspect encoder mounting for any mechanical play or vibration.

  3. 3

    Verify pulse counting parameters in the CNC.

  4. 4

    Test APC encoder with a known good reference if possible.

Ver todos los códigos en este manual (101)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas

Fuente: Fanuc Alpha i Series Servo Amplifier