SV0382

COUNT MISS(EXT)

Fanuc · Alpha i Series Servo Amplifier

¿Qué significa SV0382 ?

A count error occurred on the separate detector, indicating that pulses were missed during counting. This directly affects the accuracy of position tracking by the external detector.

Causas comunes

  • External detector is operating at speeds exceeding its counting capacity.
  • Vibration causing intermittent loss of external detector signal lock.
  • External detector internal logic circuit failure.
  • Data transmission corruption impacting pulse counts from external detector.
  • Mechanical backlash or slippage in the driven system.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Reduce the velocity command to the servo.

  2. 2

    Securely mount the external detector and associated components.

  3. 3

    Test external detector pulse counting against a known reference.

  4. 4

    Ensure clean signal transmission for the external detector.

  5. 5

    Inspect mechanical linkages for play or excessive slack.

Ver todos los códigos en este manual (101)