SV0383
PULSE MISS(EXT)
Fanuc · Alpha i Series Servo Amplifier
¿Qué significa SV0383 ?
A pulse error occurred on the separate detector, indicating that expected pulses were not detected. This impacts the accuracy of position feedback from the external detector.
Causas comunes
- Electrical noise or interference on the external detector's pulse signal lines.
- Damage or slippage on the external detector's encoder disk.
- Faulty pulse generation circuitry within the external detector.
- External noise affecting the integrity of the pulse signal.
- Incorrect pulse output configuration in servo parameters.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Measure signal amplitude on external detector output terminals.
- 2
Inspect external detector encoder disk for scratches or misalignment.
- 3
Test external detector signal generation with diagnostic tools.
- 4
Install noise filters on power supply lines to the external detector.
- 5
Verify parameter P1-01 (Encoder Pulse Output) setting.