SV0475
EXCESS ERROR (MOVE:SV)
Fanuc · Alpha i Series Servo Amplifier
¿Qué significa SV0475 ?
The servo detected that the positional deviation during traveling exceeded the parameter (No. 1838, No.1841) setting value. This indicates the axis is not accurately tracking its commanded trajectory during motion, suggesting a problem with motor power, feedback, or mechanical resistance.
Causas comunes
- Excessive accumulated error in the servo loop (SV).
- Parameter P1-54 (maximum servo error) exceeded.
- Potential servo motor winding or encoder issue.
- High load or unexpected mechanical resistance.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Verify the values of parameters No. 1838 and No.1841, which define the allowable positional deviation during travel.
- 2
Inspect the mechanical system for binding, excessive load, or increased friction that could hinder smooth motion.
- 3
Check motor performance and drive tuning for the affected axis.