SV0484

SAFETY FUNCTION ERROR (SV)

Fanuc · Alpha i Series Servo Amplifier

¿Qué significa SV0484 ?

An error occurred in the servo's safety functions. This can be due to inexecution of servo software safety functions, a mismatch between servo software and CNC results for safety functions, or an error in a servo CPU or RAM test, indicating a critical safety system failure.

Causas comunes

  • Safety function logic has detected a conflict or malfunction.
  • Safety PLC input signal mismatch or failure.
  • Incorrect configuration of safety I/O modules.
  • Overlapping or incompatible safety zones detected.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    If the cause is related to inexecution of servo software safety functions (condition 1), a servo CPU test error (condition 3), or a servo RAM test error (condition 4), replace the axis control card.

Ver todos los códigos en este manual (101)
Datos técnicos verificados. Última actualización: March 2026