Traduciendo...
PS0514

ILLEGAL COMMAND IN FLEXIBLE PATH AXIS ASSIGNMENT

Fanuc · Series 0i-MODEL F Plus Parameter

¿Qué significa PS0514 ?

This alarm signals an illegal command during flexible path axis assignment when an attempt is made to assign an axis to a path where it is already present. This condition triggers the alarm when parameter 11563 bit #4 (FAX) is set to 0, preventing the system from ignoring the redundant command.

Causas comunes

  • An illegal command has been detected within the flexible path axis assignment feature.
  • The CNC program or control logic attempted to assign an axis to a flexible path function that is not permitted by the system's configuration.
  • A command sequence related to axis remapping or flexible path control contains an error, such as attempting to assign a non-existent axis.
  • Parameter settings (e.g., P8-XX) governing flexible path axis assignments have been violated by an invalid command.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Check parameter 11563 bit #4 (FAX). If it is set to 0, the system will issue an alarm if an axis assignment command targets a path where the axis already exists.

  2. 2

    If the desired behavior is to ignore assignment commands for axes already on the target path, set parameter 11563 bit #4 (FAX) to 1.

  3. 3

    Before issuing a flexible path axis assignment command, verify the current assignment status of the target axis to avoid redundant assignments and prevent this alarm.

Ver todos los códigos en este manual (13)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas

Fuente: FANUC Series 0i-MODEL F Plus Parameter