SW0100

PARAMETER ENABLE SWITCH ON

Fanuc · Series 0i-MODEL F Plus Parameter

¿Qué significa SW0100 ?

This alarm is issued when bit 0 (PWE) of setting parameter No. 8900 is set to 1. It indicates that the parameter write enable switch is active, allowing changes to parameters. This state is often intentional during maintenance but can cause unintended modifications if left active.

Causas comunes

  • The parameter enable switch has been activated, allowing parameter modification.
  • Configuration interface is now accessible for adjustments.
  • System is ready for parameter updates.
  • Safety interlock for parameter changes has been disengaged.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Check the state of bit 0 (PWE) of parameter No. 8900 to confirm it is set to 1.

  2. 2

    Clear the alarm by turning on the external reset after parameter modifications are complete.