¿Qué significa 13 ?
The external temperature sensor connected to the battery charger is reporting a defect or malfunction. This sensor is crucial for accurate temperature monitoring, which is essential for proper battery charging profiles and safety, preventing over- or under-temperature charging.
Causas comunes
- Physical damage to the external temperature sensor cable or the sensor probe itself.
- Disconnection of the external temperature sensor from its designated input terminals on the charger.
- Internal failure or degradation of the temperature sensor component.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Verify the physical connection and wiring integrity of the external temperature sensor and its cable.
- 2
Measure the resistance of the external temperature sensor across its terminals and compare it against the expected resistance curve or specified values for its temperature range.
- 3
Replace the external temperature sensor if it is physically damaged or measures outside the expected resistance range.