Traduciendo...
16
External Start/Stop Not Closed
Fronius · Perfect Charging
¿Qué significa 16 ?
The external start/stop input, which controls the charger's operation, is detected as being in an open state. This condition prevents the charging process from initiating or continuing, as the command to run is not received by the charger.
Causas comunes
- The external start/stop button, switch, or safety contact is physically in the open (stop) position.
- A wiring break or loose connection exists in the external start/stop control circuit between the external device and the charger's input terminals.
- A faulty external start/stop relay or contactor is failing to close the circuit when commanded.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Verify the state of the external start/stop switch or button to ensure it is in the closed position (run command active).
- 2
Check the continuity of the wiring for the external start/stop circuit from the external control device to the charger's designated input terminals.
- 3
Inspect any external relays or contactors involved in the start/stop signal path for proper operation and contact integrity.
Datos técnicos verificados. Última actualización: March 2026
Fallas relacionadas
Fuente: Fronius Perfect Charging