204

TagID Data Read Failed

Fronius · Perfect Charging

¿Qué significa 204 ?

The charger was unable to successfully read data from the TagID module, even if a basic communication link might be established. This indicates an issue with data integrity or access within the TagID.

Causas comunes

  • Corrupted data within the TagID module's memory, making it unreadable.
  • Intermittent communication issues on the CAN bus, leading to incomplete or erroneous data transfers.
  • A faulty TagID module memory or processing unit.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Attempt to re-establish communication with the TagID module by power cycling the battery or charger.

  2. 2

    Inspect the CAN bus for signs of electrical noise or interference that could corrupt data.

  3. 3

    If the problem persists, the TagID module may be defective and require replacement.

Ver todos los códigos en este manual (61)