Traduciendo...
215
TagID Level Sensor Wrong Cell / Defective
Fronius · Perfect Charging
¿Qué significa 215 ?
The level sensor integrated with the TagID module is either mounted in the incorrect battery cell or is defective. This sensor is crucial for monitoring electrolyte levels in specific battery types, such as flooded lead-acid batteries, and ensuring safe operation.
Causas comunes
- Incorrect installation of the TagID level sensor in a battery cell other than the designated monitoring cell.
- An internal failure of the level sensor component within the TagID module.
- Physical damage to the TagID module or its sensor probe affecting its functionality.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Verify the correct mounting position of the TagID level sensor in the specified battery cell according to installation instructions.
- 2
Perform diagnostics on the TagID module, if available, to confirm the functionality of the level sensor.
- 3
Replace the TagID module if the level sensor is integrated and found to be defective.
Datos técnicos verificados. Última actualización: March 2026
Fallas relacionadas
Fuente: Fronius Perfect Charging