Not enough PV power or no battery power requested

Fronius · Solar Energy

¿Qué significa 306 ?

There is insufficient PV power available for feeding energy into the grid, and simultaneously, no power has been requested from the battery. This results in a short-term interruption while the inverter repeats its start-up routine. This is often displayed routinely early morning or evening due to low insolation and may not indicate a fault.

Causas comunes

  • Insufficient solar insolation (e.g., early morning, evening, cloudy weather)
  • No power request from the energy management system

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Observe the solar insolation levels and wait for sufficient sunlight

  2. 2

    Verify if any energy management commands are pending or active

Ver todos los códigos en este manual (60)