Power derating caused by too high a temperature

Fronius · Symo Advanced Manual

¿Qué significa 517 ?

The inverter's internal temperature has exceeded safe operating limits, causing it to automatically reduce its output power (power derating) to prevent damage. A warning message is displayed.

Causas comunes

  • Restricted airflow due to dust accumulation in cooling air openings or on the heat sink
  • High ambient temperatures exceeding the inverter's operating range
  • Malfunctioning cooling fan or temperature sensor

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    If necessary, purge cooling air openings and the heat sink to restore proper airflow.

  2. 2

    The fault is rectified automatically once the temperature decreases.

  3. 3

    If this status code keeps recurring, contact your system engineer for inspection of the cooling system.