231-A094

Drive lock of spindle, tool holder opened

Heidenhain · TNC CNC Controllers

¿Qué significa 231-A094 ?

This error indicates that a spindle drive was locked. This occurs when an attempt was made to switch on a spindle drive while the guard door was open AND the tool holder was also open, or due to an internal software error.

Causas comunes

  • Attempt to switch on a spindle drive while the guard door was open and the tool holder was open.
  • Incorrect status reading from the guard door or tool holder sensors.
  • Internal software error.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Ensure the guard door is securely closed and locked.

  2. 2

    Confirm that the tool holder is fully closed and locked.

  3. 3

    Check the wiring and functionality of both the guard door sensor and the tool holder sensor for proper operation.

  4. 4

    Verify the software version of the controller and update it if a known issue related to spindle interlocks exists.