CC speed greater than SRG %1
Heidenhain · TNC CNC Controllers
¿Qué significa 231-A820 ?
This error indicates that the maximum permissible velocity in the SRG (Safe Reduced Speed) operating mode was exceeded for the CC controller. This typically occurs when a feed rate or shaft speed is too high while in SRG mode, often with safety doors open, or due to incorrect parameter settings.
Causas comunes
- The maximum permissible velocity in the SRG operating mode was exceeded.
- Feed rate or shaft speed was too high before or during SRG mode activation.
- Incorrect operating mode selected (key-operated switch).
- Incorrect parameter values for SRG velocity limits.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Reduce the feed rate and shaft speed significantly before opening safety doors or activating SRG operating mode.
- 2
Check the position and setting of the key-operated switch to ensure the correct operating mode (SRG) is selected.
- 3
Verify that all parameter values related to SRG velocity limits are correctly set and correspond to the machine's safety specifications.
- 4
Inspect the machine's safety doors and their interlocks to ensure they are functioning correctly and registering their state.